2 of 12
Grozone SCC1 Advanced User Guide – March 2012 www.grozonecontrol.com
1- TEMPERATURE CONTROL WITH FAN (AND OPTIONAL HEATER)
To use this mode, you connect your cooling Fan into the FAN 120V Output, set the Slide Switch to
“Cooling” position.
BASIC
OPERATION
(lowest priority)
START / STOP THE FAN
To maintain the temperature around the DAY SETPOINT
(+/- 2°F or +/- 1°C)
ACTION OF
HIGHER
PRIORITY
STOP THE FAN TEMPORARILY
When CO2 output is activated
None, CO2 is enabled during
the Day only
RESUME FAN OPERATION AFTER A 10-MINUTE ON-DELAY
When CO2 output is deactivated when CO2 level is reached
MAINTAIN THE FAN ON
in the unlikely event of a temperature sensor failure
BASIC
OPERATION
(lowest priority)
TURN ON / TURN OFF THE HEATER
To save your plants if the lamps alone are not able to ensure a minimum
temperature in your room in a cold weather.
ACTION OF
HIGHER
PRIORITY
MAINTAIN THE HEATER OFF
in the unlikely event of a temperature sensor failure